An MSI upgrade left the app without libmpv-2.dll until it was installed a second time (B62). Costing runs before RemoveExistingProducts, saw the old DLL at the same version and skipped the copy, and removing the old product then deleted it. Both installer definitions now set REINSTALLMODE=amus; every file is private to the install directory. A taskbar pin lost its icon after a while (B63). The exe carried no icon resource, and the Start Menu shortcut's icon lived in the per-ProductCode installer cache that each upgrade deletes. build.rs now compiles the .ico into proton-stream.exe, and the shortcut has no Icon of its own (and in the WiX build is no longer advertised), so both show the exe's icon.
16 lines
646 B
Rust
16 lines
646 B
Rust
//! Compiles `proton-stream.rc` into the Windows exe; nothing on any other
|
|
//! target. `rc.exe` on an MSVC build, mingw's `windres` on the cross build
|
|
//! from Linux.
|
|
|
|
fn main() {
|
|
println!("cargo:rerun-if-changed=proton-stream.rc");
|
|
println!("cargo:rerun-if-changed=../../packaging/windows/proton-stream.ico");
|
|
if std::env::var("CARGO_CFG_TARGET_OS").as_deref() != Ok("windows") {
|
|
return;
|
|
}
|
|
// Only the GUI gets the icon; `pstr` is a console tool.
|
|
embed_resource::compile_for("proton-stream.rc", ["proton-stream"], embed_resource::NONE)
|
|
.manifest_optional()
|
|
.expect("compile the icon resource");
|
|
}
|