An MSI upgrade left the app without libmpv-2.dll until it was installed a second time (B62). Costing runs before RemoveExistingProducts, saw the old DLL at the same version and skipped the copy, and removing the old product then deleted it. Both installer definitions now set REINSTALLMODE=amus; every file is private to the install directory. A taskbar pin lost its icon after a while (B63). The exe carried no icon resource, and the Start Menu shortcut's icon lived in the per-ProductCode installer cache that each upgrade deletes. build.rs now compiles the .ico into proton-stream.exe, and the shortcut has no Icon of its own (and in the WiX build is no longer advertised), so both show the exe's icon.
5 lines
285 B
Plaintext
5 lines
285 B
Plaintext
// The exe's icon. The window sets one at runtime too, but that only lasts as
|
|
// long as the window: Explorer, the Start menu and a taskbar pin read the icon
|
|
// out of the file, and without this one they fall back to the generic one.
|
|
1 ICON "../../packaging/windows/proton-stream.ico"
|