//! One shutdown signal shared by every long-lived worker in the daemon.
//!
//! The mount used to end by unmounting and returning, leaving the drain
//! workers, the sync engine, the conflict sweep, the online probe and the local
//! indexer running on `Core` clones. In a process that exits immediately that is
//! invisible; in an in-process remount — which is how the daemon recovers from a
//! mount going away underneath it — it leaks a whole generation of threads that
//! keep writing to the database and calling the API on behalf of a mount that no
//! longer exists (`docs/BUGS.md` B44).
//!
//! The primitive is deliberately small: a flag plus a condvar. Every loop that
//! would otherwise call `thread::sleep` calls [`Shutdown::sleep`] instead, which
//! returns early — and reports `false` — the moment [`Shutdown::stop`] is
//! called, so teardown does not have to wait out a five-minute sweep interval to
//! join a thread.
use std::time::Duration;
use parking_lot::{Condvar, Mutex};
/// The daemon's stop signal. Set once, never cleared: a `Core` that has been
/// told to stop belongs to a mount that is going away.
#[derive(Default)]
pub(crate) struct Shutdown {
stopping: Mutex<bool>,
changed: Condvar,
}
impl Shutdown {
/// Whether teardown has begun. Loops check this where they would otherwise
/// start another unit of work.
pub(crate) fn is_stopping(&self) -> bool {
*self.stopping.lock()
}
/// Begin teardown and wake everything waiting in [`sleep`](Self::sleep).
/// Idempotent, because more than one path can reach teardown (a signal, the
/// kernel mount ending, a failed startup).
pub(crate) fn stop(&self) {
let mut stopping = self.stopping.lock();
*stopping = true;
self.changed.notify_all();
}
/// Wait up to `duration`, or until teardown starts.
///
/// Returns `false` if the daemon is stopping — including when it was already
/// stopping on entry, so `while shutdown.sleep(interval)` is a complete and
/// correct loop condition and no separate check is needed at the top.
pub(crate) fn sleep(&self, duration: Duration) -> bool {
let mut stopping = self.stopping.lock();
if !*stopping {
self.changed.wait_for(&mut stopping, duration);
}
!*stopping
}
}
#[cfg(test)]
mod tests {
use super::*;
use std::sync::Arc;
use std::time::Instant;
#[test]
fn sleeping_returns_early_once_stopped() {
let shutdown = Arc::new(Shutdown::default());
assert!(!shutdown.is_stopping());
let waker = shutdown.clone();
std::thread::spawn(move || {
std::thread::sleep(Duration::from_millis(20));
waker.stop();
});
let started = Instant::now();
// An hour's worth of interval, cut short by the stop.
assert!(!shutdown.sleep(Duration::from_secs(3600)));
assert!(
started.elapsed() < Duration::from_secs(5),
"stop must interrupt the wait, not wait it out"
);
assert!(shutdown.is_stopping());
// Already stopping: the next wait does not sleep at all.
let started = Instant::now();
assert!(!shutdown.sleep(Duration::from_secs(3600)));
assert!(started.elapsed() < Duration::from_secs(5));
}
#[test]
fn sleeping_runs_to_the_timeout_while_running() {
let shutdown = Shutdown::default();
assert!(shutdown.sleep(Duration::from_millis(10)));
assert!(!shutdown.is_stopping());
}
}